EN Caratteristiche della tensione fornita dalle reti pubbliche di distribuzione utilizzare un registratore conforme alla CEI EN In questo. Power quality has many meanings depending on what the power is used for. • Measuring PQ is all about deviations from normal state. • USERS. of European Norm Some countries have used EN as the basis for their national quality of supply regulations. But the standard’s statistical models.

Author: Fenribar Kazrazshura
Country: Iceland
Language: English (Spanish)
Genre: Automotive
Published (Last): 16 January 2012
Pages: 433
PDF File Size: 12.24 Mb
ePub File Size: 7.85 Mb
ISBN: 917-3-61346-898-7
Downloads: 23645
Price: Free* [*Free Regsitration Required]
Uploader: Akinocage

All voltage values outside these tolerances do not correspond to GOST and can be hazardous to appliances and equipment in one form or another. The necessity to have a standard method to identify ne sources of electrical power quality deterioration, and to evaluate accurately the actual proportion of responsibility of each of the players involved has been underlined. The project is related to the development of a sensors’ network to measure Power Quality with the ability to connect it both wirelessly and by wiringfor the analysis of a low-voltage grid.

All cases of disturbances have been implemented both upstream and downstream of the monitoring point. The purpose of the project is to create a network that can monitor systematically the power quality of a site.

Some problems come from sharing the power supply network by multiple users, others are born in facilities of the users themselves and may or may not propagate through the network with consequences against other customers.

Moreover, at higher frequencies, iron losses hysteresis losses and eddy current losses as well as the losses in the cables increase. Power Quality; smart sensors; low-voltage grid; EN standard; voltage sags measurement; disturbances of power quality.

The absorbed reactive power, taking the active power flow as a reference, will undergo an increase. Finally, electronic equipment may experience failures due to the presence of harmonics. Data are then sent to a router where they are stored in a database and reported with appropriate warnings. CEI ENCaratteristiche della tensione fornita dalle reti pubbliche di distribuzione dell’energia elettrica, We are now developing the second stage of the project consisting of designing and building the sensors network.

  LUCRETIA TITIRCA URGENTE MEDICO-CHIRURGICALE PDF

Also, a ruined or defective wiring increases the impedance of the system and therefore it amplifies the phenomenon.

New products

A method for determining location of voltage fluctuations source in electric grid. The length is assumed to be 50 m and the monitoring device a voltmeter plus an ammeter is inserted at a distance of 25 m from the transformer room. In the study of consumption of the smart-sensor the three phases of measurement, the processing and the transmission of the data packet were analyzed separately.

550160 can identify [12] four parameter, voltage in sinusoidal and non-sinusoidal regime. The router is connected directly to a PC via cable, but in the next ceu of the project a different connection, for example GSM, will be implemented to send warnings to the control stations. The arising mainly from the lack of clear theoretical and practical phenomenon definitions, studies of related situations and measurement specifications, both in standard as well as in measurement instruments and proposal of new standards in literature [13], [14].

This happens for example in managing actions, and currency exchange. For the algorithm validation a reference network has been used and the causes of voltage sags have been later implemented on it. It is also a good starting point to face with different situations in the future. The following are the basic steps of the algorithm. In this regard, data processing complies with the requirements of IEC [1].

Aspects of metrological calibration of power quality analyzers | George Seritan –

Also, once the grid voltage is distorted, a linear load absorbs a distorted current. It has also added a switch between the two serial outputs of the pic so you can monitor via the PC the. Aspects of metrological calibration of power quality analyzers. Testing and measurement techniques combined with 3rd harmonic Hz, 30V rms. In the second phase of the project the wireless network will be completed in order to implement the algorithm for analysis of disturbances directionality.

  DUMA I UPRZEDZENIA CHOMIKUJ PDF

The prototype realized at an early stage allowed us to perform the first steps and check the feasibility of some points. This single device 05160 the SPQ block of the network shown in Fig.

For example, for Class, channels. In fact, in this case the amplitude of a specific harmonic ceei increase several times as much of normal operation.

Metrel d.d. – Power Quality Analysis

A digital phase-locked loop for frequency detection. In this case, in addition to stability, a high immunity to all line disturbances is required, disturbances which presumably will be the ones that the sensor must detect and analyze. The algorithm for the detection of sags is implemented within individual measurement nodes, while that for the detection of directionality is performed in the router.

At the point of measurement it is necessary that the instrument detects the following parameters: The calibration performed in Power Quality of power supply systems is a recent concept authorized laboratories presents some technical problems, in the history of the development of electrical systems.

In case of capacitive loads, for which therefore the reactive power is generated and its direction is opposite to that of reference for the cie power, the situation is similar, but in case of event downstream is not sufficient, there is a positive deflection of reactive power, but this will also change its sign.

The main cause of voltage sags in a public network is represented by faults and in some cases by the transients overloads occurring at start up of large motors or during the insertion of large loads.

The A standard was configured to mono-phase voltage 2 and current source. It is possible however to define the “energy quality” as a perfect supply of it, which can ensure continuity of service, 50106 certain tolerances of voltage and frequency, and can be characterized by a voltage with undistorted sinusoidal waveform.